Categories
Categories
Brands
Brands
- Home
- Interventional Cardiology / Radiology / Electrophy
- ST. JUDE MEDICAL
- 2088TC-58 St. Jude Medical Tendril STS Active-fixation Bipolar Steroid-eluting Endocardial Pacing lead, 58 cm
- Home
- Cardiology
- 2088TC-58 St. Jude Medical Tendril STS Active-fixation Bipolar Steroid-eluting Endocardial Pacing lead, 58 cm
2088TC-58 St. Jude Medical Tendril STS Active-fixation Bipolar Steroid-eluting Endocardial Pacing lead, 58 cm
$2,055.00
2088TC-58 St. Jude Medical Tendril STS Active-fixation Bipolar Steroid-eluting Endocardial Pacing lead, 58 cm
$2,055.00
Product Description
2088TC-58 St. Jude Medical Tendril STS Active-fixation Bipolar Steroid-eluting Endocardial Pacing lead, 58 cm
General Description
The Tendril™ STS Model 2088TC leads are bipolar, steroid-eluting, active fixation implantable pacing leads with Optim™ insulation.
Certain Tendril STS Model 2088TC lead lengths have been tested for use in the MRI environment and are designated MR Conditional.
The Tendril STS Model 2088TC lead can be placed in either the right atrium or the right ventricle.
Features of the Tendril STS Model 2088TC leads include:
- Soft Tip Header — reduces lead tip pressure
- Optim™ insulation — a silicone-polyurethane copolymer
- Tantalum Marker Ring — to facilitate optimal lead positioning
- Active Fixation — features a rotating, extendable/retractable helix for secure anchoring
- Steroid Elution — contains a monolithic controlled-release device (MCRD), located in the tip electrode of the lead, which is impregnated with dexamethasone sodium phosphate (DSP). The steroid (DSP) decreases the inflammatory reaction of the heart during the acute stage (0-3 months post implant) of patient recovery.
- Fast-Pass™ Coating — creates a highly lubricious surface for easy insertion
PHYSICAL SPECIFICATIONS :
- Model 2088TC
- Minimum Introducer Size 6 F
- Type of Lead Active-fixation, bipolar, steroid-eluting, endocardial, pacing lead
- Lead Connector IS-1 bipolar
- Lead Lengths 46; 52; 58; 65; 100 cm
- Fixation Mechanism Extendable/Retractable helix
- Typical Number of Rotations
- for Helix Extension 6-11 (straight stylet)
- Lead Body Diameter 1,9 mm (max)
- Tip-to-Ring Spacing 10 mm
- Lead Tip Electrode (Cathode) Active titanium-nitride-coated Pt/Ir helix (2,0 mm extension)
- Tip Electrode Surface Area 6,9 mm2
- Ring Electrode (Anode) Titanium-nitride-coated Pt/Ir
- Ring Electrode Surface Area 16 mm2
- Mapping Capable with titanium-nitride-coated Pt/Ir helix
- Steroid < 1 mg dexamethasone sodium phosphate
- Inner Conductor/Outer Conductor MP35N™* coil
- Inner Insulation Silicone rubber
- OuterInsulation Optim™leadinsulation
- LeadBodyCoating Fast-Pass™coatingP