Categories
Categories
Brands
Brands
- Home
- Interventional Cardiology / Radiology / Electrophy
- LeMaitre
- LeMaitre 2012-12 Pruitt F3® Carotid Shunts, Inlying Carotid Shunt with T-Port, Diameter 9 Fr X 15 cm Length. Box of 01
- Home
- Interventional Cardiology / Radiology / Electrophy
- LeMaitre
- Pruitt F3
- LeMaitre 2012-12 Pruitt F3® Carotid Shunts, Inlying Carotid Shunt with T-Port, Diameter 9 Fr X 15 cm Length. Box of 01
LeMaitre 2012-12 Pruitt F3® Carotid Shunts, Inlying Carotid Shunt with T-Port, Diameter 9 Fr X 15 cm Length. Box of 01
$2,727.40
LeMaitre 2012-12 Pruitt F3® Carotid Shunts, Inlying Carotid Shunt with T-Port, Diameter 9 Fr X 15 cm Length. Box of 01
$2,727.40
Product Description
LeMaitre 2012-12 Pruitt F3® Carotid Shunts, Inlying Carotid Shunt with T-Port, Diameter 9 Fr X 15 cm Length. Box of 01
Product Information
- The Pruitt F3 Carotid Shunt is made with a new, more flexible material that is resistant to kinking, is color-coded for easy identification, and has 10% increased flow over the original Pruitt-Inahara Carotid Shunt
- The Pruitt F3 Carotid Shunt is secured in the vessel using occlusion balloons that eliminate the need for clamps. This reduces vessel trauma and allows for the use of a small incision, minimal dissection, and a short arteriotomy.
- Plaque endpoints can be visualized because the balloon holds the artery open during the procedure.
- This is especially important with high stenoses, when clamps cannot be used.
BALLON SPECS
- Internal carotid balloon: made of latex, the balloon has an 8 mm diameter at maximum liquid capacity of 0.25 ml.
- Common carotid balloon: has a 14 mm diameter at a maximum liquid capacity of 1.50 ml. Blue common carotid balloon corresponds to blue stopcock to simplify common carotid balloon inflation.
- Safety balloon: if the internal carotid balloon over-inflates, the extra pressure is diverted to the safety balloon. 10-12 PSI is ideal for maintaining internal carotid balloon pressure; safety balloon inflates at 13-17 PSI.
Benefits
- Balloons
Balloons hold the shunt in place and eliminate the need for clamps. - Color Coding
The common inflation lumen and depth markings are now blue, to highlight the inflation path leading from the blue stopcock to the blue balloon. - Safety Balloon & Colored Safety Sleeve
Safety balloon with a moveable plastic sheath minimizes risk of internal carotid artery balloon over-inflation (pressure diverted to the safety balloon). The safety sleeve is tinted yellow to enhance visibilty and serves as visual que to promote the correct usage. - T-Port
Blood flow and pressure monitoring can be performed through the T-port, along with infusion and flushing and removal of embolic particles. - Depth Markings
Depth markings indicate the insertion length of the shunt for both the internal and external inflation lumens. - Flexible and Resistant to Kinking
The Pruitt F3 shunt is designed with a more flexible material that’s also more resistant to kinking.